Ex Stainless steel pressure equalisation element M

Use our pressure compensation elements in your ROSE enclosure to adapt the internal pressure of an enclosure to the ambient pressure and thus avoid condensation in highly sealed enclosures.

Technical Data

Atmosphere

G/D

Zone

1

2

21

22

Type of ignition protection

Ex e

Equipment group

II

Category

2/3

Material

1.4305 Stainless Steel

Ingress protection

IP 66 to EN 60529

Temperature range

-40°C to +105°C

Product Range
Order-No.TypeCable ØWrench SizeThread LengthDatasheetInquiry
08.50 11 12 M12 x 1.5 10 mm 17 mm 17 mm